Pool heater says lo -

 
The EnergyRite residential heater offers power to guarantee speed heating for any size pool or spa, from 150,000 btu/hr to an industry-maximum 400,000 btu/hr. And Lochinvar's engineering delivers the highest thermal efficiency in its class. It's a combination that provides the industry's fastest heat-up time, and uses less energy so homeowners .... Gateway garden center hockessin

1 Common Issues With Jandy Pool Heaters. 1.1 Pool Heater Not Turning On. 1.2 Pool Heater Not Igniting. 2 Pool Heater Troubleshooting Tips. 2.1 Check The Pilot Light. 2.2 Inspect The On/off Switch. 2.3 Test The Pressure Switch. 2.4 Clean Connections. 2.5 Resetting The Pool Heater.DIYin' it with Laughing Moms! Today we fix the air flow problem on our Jandy LT400N-L Pool Heater. Let us know if you find this video helpful and if you'd li...If you're looking for help fixing your Hayward Pool Heaters, look no further! Our comprehensive Hayward Pool Heaters error code guide will explain common iss...1. Turn off power at toggle switch and source, then re-establish power. 2. If code reappears, replace board as memory has failed. FAN. Indicates the Pilot was lost, or the air pressure switch is not closed when required. 1. Check for correct incoming power at fan relay- 120V or 240V and at fan motor. 2.Step 4: Thread the pressure gauge into the air relief valve in a clockwise direction. Use an open-end wrench to tighten the last half-turn. Do not over tighten. Step 5: Turn on the power to the pump at the breaker box. Close the air relief valve when a continuous stream of water flows out.Follow the included steps to place the heater in bypass mode for external control. Step 1. Press the ‘MENU ICON’ button to place the heater in ‘STANDBY’ mode. Step. The ‘SPA’ indicator should illuminate & the display should show the Max Temp set point. Step 2. Press and hold the minus & plus buttons for 3 seconds.May 17, 2022 · There can be a wide range of reasons why your Raypak pool heater won’t ignite. A clogged pilot orifice, faulty pilot assembly, defective flame sensor and blower stops operating are the main culprits. Besides obstructed pool filters, insufficient pump pressure, broken gas valve, blocked burner orifice and tripped safety switches are also ... Adjust the water flow or call a professional if the pressure is too low. Clean the Filter: A dirty or clogged filter can cause Hayward Heater CE Code errors. Clean the filter thoroughly and replace it if necessary. This will improve the heater’s efficiency and prevent future issues. Inspect the Ignition System: If the above steps do not ...To turn heater on: Press & release the set button four times until “Off” appears. Press down button twice then “No” appears. Heater is now on. Pool & Spa lights will illuminate beside display indicating heater is on. Use the up or down arrows to set desired temperature.Heater reads “OFF” on the control board when any button is pressed.Turn the thermostat all the way up on the heat pump. These units are not compatible with 3 wire remotes. For 2 wire air switch installations remove the jumper between terminals 1 & 2 and replace it with the 2 wires from your switch. Set the thermostat on the heat pump to the desired temp. Wiring Diagram HPABG / HP380.Aug 21, 2023 · Check the Gas Valve. Start by ensuring that the gas valve is open and allowing the flow of gas to the pool heater. If the gas valve is closed or partially closed, the heater won’t receive the necessary fuel to ignite. Make sure the valve is fully open and functioning correctly. Many pool heaters, like our Lo-Nox selection, are designed to minimize nitrogen-oxide levels, in turn making them more environmentally-friendly. Since some state laws mandate a Lo-Nox pool heater system, it’s important to be aware of your state health codes. For example, Lo-NOx is required for 5 counties in Southern California, and for all ...If the pressure-gauge reading is too low, check and clean out the pump pot and skimmer basket or even the eye of the pump impeller. If the pressure gauge reads “normal,” proceed. Check the on/off switch. Gardeners or others may have turned the unit off. Check the thermostat. It may be turned down too low.Below is the troubleshooting guide for Hayward pool heater error codes. Error codes show up on the digital screen of the H-Series H150, H200, H250, H300, …Faulty water temperature switch, malfunctioning vent pressure switch, and defective temperature limit switch are accountable for displaying the Hayward pool heater LO code. Also, the damaged flow switch diaphragm and clogged filter are responsible for showing this code on your pool heater. However, going through the article, you will learn all about reasons behind LOWhen it comes to enjoying your pool year-round, a properly sized pool heater is crucial. Choosing the right size heater ensures that your pool stays at the desired temperature, reg...What it means: Lo P: the refrigerant system’s low-pressure sensor detects low refrigerant, low air flow, or low air temperature. Lo A: the low-pressure switch was triggered and outside air temperature is under 50 degrees. How to fix it: Make sure pool pump is receiving enough water. Check that pool pump is sending water to the heat pump.If your Hayward pool heater is displaying the LO code, it means that the limit string is open and the heater will shut down and enter lockout mode. To fix the problem and close the …One of the reasons it is so hard to diagnose technical issues online is because every pool and every heaters are different. ... It means the temp is too “LO” for the heater to operate. Reply. Tom ... off, though the spa was hot as expected. The next day, it wouldn’t ignite and ER04. Now, on my pentair, the panel says ER04 = Bad ignition ...Your pool heater needs enough water pressure to run properly, usually at least 40 GPM (gallons per minute). If your heater is not getting a steady stream of water, it could be due to a clogged filter or …It is the quickest heater among those on our list. The Hayward heater will increase the temperature by 2-4°F in an hour. It is 2 times quicker than any other heat pump that we have reviewed. The heater is the best option for those who have a connection to natural gas.One of the most common calls we receive during season is the FLO error on a pool heater. Learn more about what causes this error and how we resolve it.If you're looking for help fixing your Pentair Pool Heaters, look no further! Our comprehensive Pentair Pool Heaters error code guide will explain common iss...Pool noodles are one of the weirdest pool toys. They float, and that's about the only reason they're good for water games. Do yourself a favor and use them around the house instead...Troubleshooting a Raypak pool and spa heater. Erroro indicated shorted sensor and heater is not lighting. We walk through the complete process to make the ...Just starting up my pool. Pump is running, water is flowing through heater, heater plugged in, gas on. Service panel says Lo and “service”. I've tried switching mode to pool with a heat setting of 80F … read moreThe Universal H-Series Low NOx heater has an 84 percent industry-leading thermal efficiency and complies with all current California air quality emission standards. The low NOx emission makes it a perfect choice for the environmentally concerned pool owner. Enjoy a warmer pool this season without your fuel costs skyrocketing.Heaters are expensive pieces of equipment and sometimes the pool owner can do more harm than good. A good rule is, when in doubt- give Pentair’s technical support a call. They will troubleshoot the heater with you over the phone and help come up with viable solutions.Locate the pilot light assembly on your pool heater. 2. Turn the gas control knob to the “Off” position and wait for 5 minutes. 3. Turn the knob to the “Pilot” position and press it down. 4. While holding down the knob, use a …At this juncture, that's the only way we'll locate which switch it is and prove which one is giving you the LO code. There is the water pressure switch which is first in line in the circuit, and then there is the air proving switch which is second in line in the circuit, and then we have a couple of high limits switches; some of the older models have a …Aug 21, 2023 · Check the Gas Valve. Start by ensuring that the gas valve is open and allowing the flow of gas to the pool heater. If the gas valve is closed or partially closed, the heater won’t receive the necessary fuel to ignite. Make sure the valve is fully open and functioning correctly. Turn off the electricity and gas going to the pool heater. Open the faceplate of the heater, then locate the pronged ignitor. Remove the retaining bracket and screws, then disconnect the ignitor from the motherboard’s wires. Contact the manufacturer for a like-for-like ignitor part number, then attach it to the motherboard’s wires.5, 05. Temperature sensor error, or water is dangerously hot. 6, 06. High limit manual reset on heater is tripped. 7, 07. Stuck heater relay. 9, 09. Water pressure fault; pump may be air locked, or water level low. 131.For the best operation of your pool heater, Raypak recommends keeping your water pH between 7.3 and 7.4 with a total alkalinity of 120 to 150 ppm and calcium of 200 to 300 ppm for any fiberglass pool heated between 68 and 88°F. The maximum salt should be 4,500 ppm and maximum dissolved solids should be 3,000 ppm.To convert your electric pool heater to gas, follow these general steps: Turn off all power supply going into your existing electric pool heater. Dismantle old connections from natural heating elements connected in electrical junction box which contains switches, fuses inside or separate nearest fuse box if accessible.combustion process is transferred directly to pool water. This high efficiency improves your heat up time and reduces your energy cost as shown by the formulas below: 3 TIME = Pool/Spa Volume Time:X 8.34 X ΔT Heater BTU X 0.96 ENERGY COST = Heater BTU Heater BTU:X Time 100,000 X Gas Price Hours required to heat pool Pool/Spa … Troubleshooting Guide For Pentair Pool Heat Pumps. Pentair Technical Support: 800-831-7133. WARNING RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. Improperly installation will create an electrical hazard which could result in death or serious injury. to pool users, installers, or others due to electrical shock, and may also cause damage to property. LO means low water pressure. For safety, the heater doesn’t turn on when there might be too little water getting to it, which prevents overheating/fire. Per my pool service, first step is to backwash. There could be another issue causing the error, but needing to backwash is the most common cause. Space heaters make it simple to heat a small space. Many people use them to heat outdoor spaces as well as rooms within a home that tend to stay cold. Like all heaters, though, spa...I fixed Lo error! hayward spa heater was giving me a LO error when I turned it This is how I fixed it within less than a minute easy steps.You can also have something called a pressure switch located on your heater element which does the same thing. These sensors are there to protect the heater from running dry, so if the water flow drops below a certain level the sensors will tell the heater to shut down in order to protect itself from burning out.Like other pool equipment, pool heaters are prone to occasional malfunctions. Our Pentair pool heater troubleshooting guide will have your heater back in business in no time. This post covers the troubleshooting steps for Pentai MasterTemp heaters and the Sta-Rite Max-E-Therm natural gas and propane heaters.Reopen your pool when the temperature gets above 60°F (15.5°C). But if the outside air temperature is between 40°F (4.4°C) and 60°F (15.5°C), you could install a pool heater before the salt cell so you can continue to run your chlorine generator. It will however be expensive to run a pool heater when temperatures are low.Some Chrysler vehicles come equipped with manual heating and air conditioning, three-zone temperature controls and, on some vans, manual climate controls for the rear passengers. A...1. Turn off power at toggle switch and source, then re-establish power. 2. If code reappears, replace board as memory has failed. FAN. Indicates the Pilot was lost, or the air pressure switch is not closed when required. 1. Check for correct incoming power at fan relay- 120V or 240V and at fan motor. 2.Answered in 5 hours by: PitschPlumbing. Generally, LO refers to the pressure switch, water pressure. This can be caused by either the diaphram in the flow switch has failed or the …It should measure between 9° and 12°F (5° and 7°C). If it does, then your heat pump is operating normally, and your heating failure is most likely due to inadequate run time of the heat pump. Remember, your heat pump’s run time depends on your filtration pump’s operation. Evaporator coil obstructions. Without sufficient air inflow and ...Defective Pressure Sensor/switch (Most Common) The purpose of the pressure switch is to ensure that water is flowing through the unit before it allows the heater to turn on. The pool pump must be ON and your filter clean for the switch to close and allow voltage to pass through. Test the voltage reading on the pressure switch with a multimeter.Fits hayward universal h-series low nox pool heater models h150fdn, h150fdp, h200fdn, h200fdp, h250fdn, h250fdp; Also fits hayward universal h-series low nox pool heater models h300fdn, h300fdp, h350fdn, … by Troubleshooting Lab. To troubleshoot a Raypak pool heater, check the power source, ensure proper gas pressure and air supply, and inspect for any clogged filters or low water flow issues. Additionally, make sure the unit’s time clock is set to the “On” position, and verify that the gas is turned on and the propane tank has fuel. This includes the switch on the heater and the main power supply breaker for the heater. Ensure that all valves are in the OPEN position. This includes the gas valve, gas supply valve, plumbing and filter valves. Make sure the pilot light is lit. If it isn't, continue to the following gas pool heater troubleshooting step.Heat pump troubleshooting guide for Pentair pool heaters. Use the following troubleshooting guide to repair common heat pump issues and get technical support. Call Us Nationwide: 1-800-741-9956. West: 213-291-9276 Southwest: 214-764-8551 Midwest: 312-229-0026 Northeast: 631-223-7175 Southeast: 239-247-5878 or 954-866-1644. …A car’s heater does not generate heat if the coolant level is low or restricted by buildup, if the water pump failed or if the thermostat is broken. The heater fan is also sometime...Answered in 5 hours by: PitschPlumbing. Generally, LO refers to the pressure switch, water pressure. This can be caused by either the diaphram in the flow switch has failed or the …If your heater does not operate or does not heat your pool water get technical support to repair common issues. Call Us Nationwide: 1-800-741-9956. West: 213-291-9276 Southwest: 214-764-8551 Midwest: 312-229-0026 Northeast: 631-223-7175 Southeast: 239-247-5878 or 954-866-1644. Trustpilot.Feb 20, 2017 ... Fixing a Pentair Minimax heater that turns on heat and then shuts off after a minute. Exhaust fan works and air switch works?The Jandy Jxi Pool Heater 400 Natural heater sets the standard in pool and spa heating technology with its ultra-compact size, lightweight design and installation flexibility — making it a top choice for pool professionals and pool owners everywhere. The high-efficiency, low-NOx JXi is available in three BTU sizes, 200K, 260K, 399K, and ...Best Pool Heaters: Comparison Table. Best Pool Heaters 2022: Reviews. BEST OVERALL: Hayward H400FDN Universal H-Series 400,000 BTU Pool and Spa Heater. BEST SOLAR HEATER FOR ABOVE GROUND POOLS: Intex 28685 Solar Heater Mat. BEST ABOVE GROUND POOL HEATER: Hayward HP50TA 50,000 BTU Heat Pro Heat Pump.by Troubleshooting Lab. To troubleshoot a Raypak pool heater, check the power source, ensure proper gas pressure and air supply, and inspect for any clogged filters or low water flow issues. Additionally, make sure the unit’s time clock is set to the “On” position, and verify that the gas is turned on and the propane tank has fuel.Apr 12, 2020 ... Pool Basics: How To Start/Light a Hayward H-Series Pool Heater ... How use your Pool Heater and ... hayward spa heater was giving me a LO error.Sep 10, 2023 · September 10, 2023 by Sayed Sayeedur Rahman. To service the heater light on a pentair mastertemp, follow these steps: check the power supply, inspect the igniter and flame sensor, clean or replace any faulty parts, and reset the system if needed. These actions will ensure the heater light is functioning properly and heating the water ... Sep 10, 2023 · To fix low flow on your pool heater, follow these steps: 1. Check the filter: make sure the filter is clean and not clogged with debris, as this can restrict water flow. 2. Inspect the pump: verify that the pump is functioning properly and is set to the correct speed. Why does my pool heater say no flow? Usually, the pool heater says no flow, which means that debris or dirt causes it to clog. Another reason is that the water level is low and blocks the basket due to dirt. A Must-Read: Best Pool Accessories. You will learn that a clogged filter and impeller results in poor water flow as you read on.Feb 2, 2023 · Monthly Filter Cleaning: Dirt can accumulate in your filters, causing restricted water flow which, in turn, might trigger the ‘LO’ code. It’s therefore crucial to clean your filters monthly, or more often if your pool sees heavy use. Adequate Water Flow: Ensure your pump is delivering the right flow rate to the heater. To convert your electric pool heater to gas, follow these general steps: Turn off all power supply going into your existing electric pool heater. Dismantle old connections from natural heating elements connected in electrical junction box which contains switches, fuses inside or separate nearest fuse box if accessible.This time of year, you’ve gotta do some work to keep your home warm and cozy. Christmas lights, decorations, an extra throw blanket on the couch. And, of course, a space heater. Bu...I fixed Lo error! hayward spa heater was giving me a LO error when I turned it This is how I fixed it within less than a minute easy steps.Medallion Energy 3055 Tech Park Way Deland, FL 32724 407-786-0000. Hours Mon-Fri: 8am – 7pm Saturday: 9am – 5pm Sunday: By AppointmentThe instructions below will walk you through replacing the Pentair MasterTemp 400 Ignition control module. Step 1: Take off the left side panel of the heater. Step 2: Disconnect the system from the Max-E-Therm heater. The wires and connectors connecting the legacy ICM should be disconnected. Improper gas pressure: If your pool heater is gas-powered and the gas pressure is too high or too low, it can cause whistling or screeching noises. Residential pool heater issues: Noise-related problems; Noise-related problems in residential pool heaters can be quite disruptive, but they can also indicate more serious issues. The MiniMax NT Low NOx is a compact, lightweight, efficient, induced-draft, gas fired high performance pool and spa heater that can be directly connected to schedule 40 PVC pipe. The MiniMax NT Low NOx, also comes equipped with the Pentair multifunction temperature controller 7800 which shows, at a glance, the proper functioning of the heater.Best Overall, Electric: FibroPool Swimming Pool Heat Pump at Amazon ($2,200) Jump to Review. Best Overall, Gas: Raypak Digital Low NOx Natural Gas 266,000 BTU Pool Heater at Amazon ($2,999) Jump to Review. Best Propane: Hayward Universal H-Series at Amazon ($3,999) Jump to Review.Follow the included steps to place the heater in bypass mode for external control. Step 1. Press the ‘MENU ICON’ button to place the heater in ‘STANDBY’ mode. Step. The ‘SPA’ indicator should illuminate & the display should show the Max Temp set point. Step 2. Press and hold the minus & plus buttons for 3 seconds.Turn off the power to your pool heater. Locate the high limit and temperature sensor, usually found near the burner assembly. Remove the wires from the high limit and temperature sensor. Use alligator clips to connect the two wires together. Turn on the power to your pool heater and check if it starts working properly.You don’t need a fancy test meter to troubleshoot a pool heater. ELECTRONIC POOL HEATER TROUBLESHOOTING GUIDES. For our example heater, we will be using the Old Teledyne Laars Series I & Series II Spark Ignition heaters, made from 1986-1997; but the concepts apply to electronic heaters made by Raypak, …Clean the thermocouple, and then try to relight the pilot. If the light continues to go out, you probably need to replace the thermocouple. Or you might even need to replace the entire pilot assembly. The pool heater won’t ignite. First, check that your heater is turned on and the gas valve is in the “on” position, and be sure that the ...LO Code Pages 40-43 IF Code Pages 44-46 AC Code Page 47 AO Code Page 48-50 Temperature Lock Out Page 51 Heat Exchanger Page 52-53 ... Heater must then be in Spa or Pool Mode for operation. The heater will fire when instructed by the external control. Control Configuration- Two wireHowever, that does not necessary mean it can heat the pool to 80° on a 20° day. As a rule of thumb, the highest water temperature rise you can get from an air-source heat pump under ideal conditions is 30°. For example, if the outside temperature is in the 40s, you can expect the pool to warm up only to the 70s.The most common issue when a swimming pool heater won’t heat is also the simplest one, a dirty swimming pool filter. They say that up to 70% of all ‘My heater won’t heat’ service calls are due to low water flow. The heater has a pressure switch and an internal bypass, to ensure the correct amount of incoming water flow, before it will ...The High-efficiency, High-tech Heater for Pools Up to 15,000 Gallons. The MasterTemp 125 Heater provides energy-savings and advanced operating features that were only available from much larger heaters. With its revolutionary pre-mixed gas combustion technology, the MasterTemp 125 Heater offers 82% thermal efficiency, the highest in its …Space heaters make it simple to heat a small space. Many people use them to heat outdoor spaces as well as rooms within a home that tend to stay cold. Like all heaters, though, spa...Fits hayward universal h-series low nox pool heater models h150fdn, h150fdp, h200fdn, h200fdp, h250fdn, h250fdp; Also fits hayward universal h-series low nox pool heater models h300fdn, h300fdp, h350fdn, …The most common issue when a swimming pool heater won’t heat is also the simplest one, a dirty swimming pool filter. They say that up to 70% of all ‘My heater won’t heat’ service calls are due to low water flow. The heater has a pressure switch and an internal bypass, to ensure the correct amount of incoming water flow, before it will ...Apr 12, 2020 ... Pool Basics: How To Start/Light a Hayward H-Series Pool Heater ... How use your Pool Heater and ... hayward spa heater was giving me a LO error.My pool heater would not fire and was showing the LO (low flow) code. This shows where the adjustment knob is on the pressure switch and insight into how to ...Available in 150,000, 200,000, 250, 000, and 400,000 BTUs, the Universal H-Series heater can raise the temperature of an 800-gallon pool 30 degrees in less than an hour—you’ll feel the benefits the moment you step into the water. The Hayward Universal H-Series Low NOx can be added to inground pool kits sold by Pool Warehouse!I fixed Lo error! hayward spa heater was giving me a LO error when I turned it This is how I fixed it within less than a minute easy steps.heater and to all metal parts of swimming pool or spa, and to all electrical equipment, metal piping (except gas piping), and conduit within 5 ft. (1.5 m) of inside walls of swimming pool or spa. IMPORTANT -Refer-ence NEC codes for all wiring standards including, but not limited to, grounding, bonding and other general wiring procedures.

20. Posted February 18, 2011. My Jandy LXi heater seems to not be working. It looks like it normally does, even lets me choose between Pool or Spa. It says Remote TSTAT enabled, which I believe is for my Jandy remote. I go to fire it up (booster pump is running already of course) and nothing happens. After a minute or so, it says "Ign Fault".. Perc ten i just popped a perc ten lyrics

pool heater says lo

Jan 8, 2019 · Like other pool equipment, pool heaters are prone to occasional malfunctions. Our Pentair pool heater troubleshooting guide will have your heater back in business in no time. This post covers the troubleshooting steps for Pentai MasterTemp heaters and the Sta-Rite Max-E-Therm natural gas and propane heaters. Two achievements made by the Los Reyes Católicos was the unification of Spain and the retaking of Granada from Moorish occupation. The Los Reyes Católicos, meaning the Catholic Mon...Are you experiencing a LO code on your Hayward H-Series pool heater? If so, give this video a watch for a few basic tips on how to work through the issue you...The pool heater is powered through an electrical outlet. It comes with two hoses and attachments, one of which connects the heater to a filter pump and the other to a pool. Water is pumped into the …1 Common Issues With Jandy Pool Heaters. 1.1 Pool Heater Not Turning On. 1.2 Pool Heater Not Igniting. 2 Pool Heater Troubleshooting Tips. 2.1 Check The Pilot Light. 2.2 Inspect The On/off Switch. 2.3 Test The Pressure Switch. 2.4 Clean Connections. 2.5 Resetting The Pool Heater.Two achievements made by the Los Reyes Católicos was the unification of Spain and the retaking of Granada from Moorish occupation. The Los Reyes Católicos, meaning the Catholic Mon...Lo-Nox. Before purchasing a heater, a pool owner should become more acquainted with their state health and safety codes. Lo-Nox heaters are a more environmentally safe way to heat your pool. ... Jay Shah says: August 31, 2021 at 3:48 PM. Hello, Trying to decide between a 400k btu cupro nickel heat exchanger natural gas …Mark shows us in this video how to do troubleshooting for a heater, he walks us through all of the steps. For all the pool knowledge you're looking for, chec...Pool noodles are one of the weirdest pool toys. They float, and that's about the only reason they're good for water games. Do yourself a favor and use them around the house instead...If you're looking for help fixing your Pentair Pool Heaters, look no further! Our comprehensive Pentair Pool Heaters Troubleshooting guide will explain commo...Aug 8, 2021 · NJ. Aug 7, 2021. #1. Hello, I have a H150FDN pool heater. It's worked all summer so far, but last week I noticed that it would turn on for a few minutes then turn off and show Lo. The filter is clean and the output is strong. I ordered a new pressure switch, but in the meantime I took the two wires that connect to the switch and made a jumper ... Heater must then be in Spa or Pool Mode for operation. The heater will fire when instructed by the external control. Control Configuration- Two wire Note: 104° maximum temperature. Step 1: Step 2: Step 3: Press the Mode button to place the heater in Standby Mode. Hold the Down Arrow and Mode buttons simultaneously for 3 secondsYou need to put the heater in STANDBY Mode to get the bO code on the heater display. Press the mode button once to get the heater in STANDBY Mode. First, press and hold on to the Down key. Then, press and hold down the MODE key as well. You need to keep holding both keys for about three seconds. At this point, the “bO” message …September 10, 2023 by Sayed Sayeedur Rahman. To service the heater light on a pentair mastertemp, follow these steps: check the power supply, inspect the igniter and flame sensor, clean or replace any faulty parts, and reset the system if needed. These actions will ensure the heater light is functioning properly and heating the water ...Aug 9, 2015. 30. macomb twp. Jun 14, 2016. #1. I have Hayward H150FDN Universal H-Series, Low NOx, 150,000 BTU, Natural Gas, Pool and Spa Heater and I …new heater. set temp to pool on 90. Heater turmed on then one minute later turned off says 79 on display. Water Temp 79. Wont turn back on to heat pool. Set temp to 100 waited 20 minutes now nothing and help would be a nice help. Tech support has been busy for some time now. Mark.

Popular Topics